Vertical Branch Style - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Isogen Isometric Drawings

Language
English
Product
Intergraph Smart 3D
Subproduct
Drawings and Reports
Search by Category
Help
Smart 3D Version
13
Isogen Version
13.0(2016)

Controls the drawing depiction method used when a vertical branch connection is made to a sloping (falling) cable tray using a special zero length bend component. This special bend (which has no length) is used to carry the angle between the vertical branch and the sloping cable tray.

  • True displays the short tee branch leg section of cable tray skewed. Olets have an orientation message instead of a skewed section. Both are dimensioned separately to the connecting cable tray. This is the default setting.

  • False connects the vertical branch straight into the main cable tray so that there are no separate skew sections. Olets do not have an orientation message. Both are included in a single inclusive dimension.

  • Where olets are used in such cases, a text message indicates the orientation direction if the branch is not developed.

  • In both cases, the angle between the vertical branch and the sloping (falling) cable tray is indicated.

Defines:

Option Switch - 68
I-Configure - Drawing.Format.SkewInVerticalBranch