If an isometric extraction fails, Isogen returns an error number that can be referenced from an error message or the extraction error log within the software. Descriptions for the Isogen error message numbers are shown in the table below.

Error Value

Description

-1001

Did not create the specified Pre/Post processor.

-1002

Pre/Post processor has crashed.

-1003

Pre/Post processor has timed out, and the external process has been killed.

-1004

Pre/Post processor has timed out, but the external process cannot be terminated (and is therefore still running).

-1

Error in Isogen data. Check message file.

-2

Isogen .dll failed to load (possible installation problem, missing dependent file, etc.) or crash occurred during execution, which has been trapped by the error handler.

-3

Isogen thread filed to finish. Possible execution loop that has been stopped by Personal Isogen.

0

Iso created successfully.

1

Personal Isogen cannot find the isometric directory specified.

2

Invalid Style for this project. The specified Style cannot be found under the specified project.

3

Specified Project not found. The specified project cannot be found.

4

IDFGEN handshake failed. The handshake passed to the idfdll.dll has not been verified.

A number of other "unexpected" failures have been found to generate this error.

5

Could not access specified PCF in TEMFILES.

6

ISOGEN DLL failed to establish current folder.

7

ISOGEN DLL failed to change folder.

8

The handshake passed to the pisodll.dll has not been verified.

9

Personal Isogen failed to produce a valid drawing. View message file for details as there are many possible causes.

10

ISOGEN DLL failed to restore working folder.

11

IDFGEN DLL failed to establish current folder.

12

IDFGEN DLL failed to change folder.

13

IDFGEN did not complete successfully. View message file for details. One common cause is that the components in the PCF do not form a connected system.

14

IDFGEN DLL failed to restore working folder.

15

IDFGEN could not delete IPISOGEN\PROGRAMS\FOR036.DAT from a previous run.

16

IDFGEN was unable to create ISOGEN.IDX file. Error opening isogen.idx. Error closing isogen.idx.

17

IDFGEN was unable to copy ISOGEN.FLS to the PROGRAMS folder. The following errors may have occurred:

Error allocating memory to store a line.

Zero line length encountered.

Error opening source isogen.fls (in specified project\isotype).

Error opening target isogen.fls (in pisogen\programs).

Error closing source isogen.fls (in specified project\isotype).

Error closing target isogen.fls (in pisogen\programs).

18

No description available from Alias Personal Isogen.

19

Personal Isogen handshake failed. The handshake passed to the pisogen.dll has not been verified.

20

Unknown error in Personal Isogen. An unexpected path through the software has occurred.

21

PISOGEN DLL could not find current working folder. The current folder cannot be identified.

22

PISOGEN DLL could not change foler to \PISOGEN\PROGRAMS.

23

Isogen did not write banner to message file. (Probably cannot find message file path). The following errors may have occurred:

  • Error opening isogen.fls.

  • Unable to find MESSAGE line in isogen.fls.

  • Error closing isogen.fls.

  • Error opening message file.

  • Error closing message file.

24

PISOGEN DLL has been unable to restore current working folder.

26

The following errors may have occurred:

  • Error opening i-gen.fls for reading.

  • Error opening isogen.fls for writing.

  • Error opening options file specified in i-gen.fls.

  • Error closing options file specified in i-gen.fls.

  • Error opening i-gen.opl for writing.

  • Error closing i-gen.opl.

  • Error closing i-gen.fls.

  • Error closing isogen.fls.

26

Problem with the specified isometric root folder.

27

Problem setting the current isometric root folder.

28

Invalid file extension.

29

Not applicable when running Isogen.

30

Warning occurred creating a POD (intermediate) file.

31

Error occurred creating a POD (intermediate) file. Error occurred during "pass 1" when the input IDF file is preprocessed.

32

Error occurred creating a POD (intermediate) file. Error occurred during "pass 2" when the POD file is being created from Isogen data.

33

Failed to load PODGRAPHICS DLL - used in the creation of graphics output files such as DWG and IGR.

34

PODGRAPHICS process failed - IE. a graphics specific process has failed - for example, user requested IGR output but SmartSketch is not installed.

35-40

Not used at this time.

41

Cannot get path to system temp folder.

42

System temp folder does not exist.

43

Unable to set bore units to those specified in the input file.

44

Unable to perform macro substitution in style ISOGEN.FLS.

45

Unable to restore original style ISOGEN.FLS.

46-49

Not used at this time.

50

Project disk is full - unable to create new output files.

51

File containing temp folder is full - unable to process file.

52-999

Not used at this time.

1000

Expected files missing in Style - E.G. no FLS, no options file.

1001

Requested units combination is inconsistent - probably means a combination of metric bore and imperial coordinates.

1002

Invalid drawing format requested.

1003

Problem removing an Isogen message file.

1004

Line in the options file has invalid format.

1005

Too many switches in the options file.

1006

Too few switches in the options file.

1007

MicroStation design file output requested but MS_EXE environment variable is not defined.

1008

MicroStation design file output requested but MicroStation not installed.

1009

MS_EXE environment variable does not end with a \.

1010

ISOGEN.FLS missing in Style.

1011

Options file missing specified in ISOGEN.FLS is missing.

The following warning messages may also display:

Error Value

Description

1999

Isogen has returned a FAIL for one or more drawings in the set. This means it has been unable to layout the drawing successfully.

2001

Inconsistent units combination (imperial coordinates and metric bores).

2022

IDFGEN has detected a disconnected pipeline that cannot be resolved. This is known as a HARD disconnect. Drawings have still been created that will indicate the cause of the disconnection.

2023

IDFGEN has detected a disconnected pipeline that cannot be resolved, but the disconnected items are not considered to be fundamental to the pipeline. This is known as a FLOATING disconnect. Drawings have still been created that will indicate the cause of the disconnection.

2024

IDFGEN has detected a disconnected pipeline that has been resolved. This is known as a SOFT disconnect. Drawings have still been created that will indicate the cause of the disconnection.