Specifies properties for delaying recalculation of the imported plate system that you are editing.
Delay Settings
Molded Forms Delay
Delays recalculation of Molded Forms objects. The objects are instead added to the To Do List.
Plate Split Delay
Delays splitting of the plate system by seams.
Range Settings
User range of change
Restricts recalculation to one or more range boxes that you specify. Type low and high values for X, Y, and Z in User Range to create a box.
System range of change
Restricts recalculation to a range box created by the software and based on the X, Y, and Z differences between the old and new imported plate systems.
User Range
Low
Specifies the lowest value along a coordinate system axis. Type values for X, Y, and Z.
High
Specifies the highest value along a coordinate system axis. Type values for X, Y, and Z.
Modify
For a selected existing row in the Display Range grid, changes the Low and High values to the new values.
Add
Adds a new row of Low and High values to the Display Range grid.
Display Range
Displays range boxes where recalculation is delayed. Each row in the grid contains low and high coordinate values for a range box.
You can select a row in the Display Range grid. When a row is selected, the range box displays in a graphic view.
Clear All
Clears row selection in Display Range.
Select All
Selects all rows in Display Range.
Delete
Removes the selected row from Display Range.
Delete All
Removes all rows from Display Range.
OK
Accepts the values and closes the dialog.
Cancel
Rejects the values and closes the dialog.
Apply
Accepts the values but does not close the dialog.