Map HVAC components to Smart 3D components and fittings - Intergraph Smart 3D - 13 - Administration & Configuration - Hexagon PPM

Intergraph Smart 3D PDMS Conversion to Smart 3D

Language
English
Product
Intergraph Smart 3D
Search by Category
Administration & Configuration
Smart 3D Version
13
Smart Interop Publisher Version
16

The following steps illustrate how to map PDMS HVAC components to Smart 3D components and fittings. This mapping is required prior to importing PDMS HVAC component data into Smart 3D.

  1. Navigate to the [Product Folder]\3DRefData\SharedContent\Data\Translators\PDMSS3DImport folder, and open the PDMSS3DImportMapping.xls workbook.

  2. Locate the S3DHVACXMLPartTypeMap sheet, and then map the PDMS HVAC GType present in the .datal and .att file to the appropriate Smart 3D value, such as Component or Fitting.

  3. Save your changes.

  4. Locate the SPREFS3DHVACIdentifierPttrnMap sheet, and then map the PDMS component SPRE values to the relevant Smart 3D HVAC part numbers.

  5. Save your changes.

  6. Locate the HVACAdditionalAttsMap sheet, and then map any Smart 3D part number additional attributes.

    HVAC Best Practive EXAMPLE 3

  7. Save your changes.

We recommend that you map the Smart 3D duct straight part to PDMS STRT component to create an accurate model in PDMS.