Click Place Fireproofing Command on the vertical toolbar.
-
Clear the By Rule option to set the fireproofing properties.
-
Select the member to which you want to apply the different types of fireproofing.
-
Set Condition to Add.
-
In the Insulation Spec box, select the first insulation specification to use.
-
In the Encasement box, select the first encasement to use.
-
Define the fireproofing setbacks that you need for this fireproofing using the Reference 1, Distance 1, Reference 2, and Distance 2 boxes.
-
Click Accept .
-
Verify the fireproofing is where you want it on the member. Adjust the setback properties if needed.
-
Click Finish to place the first fireproofing type.
-
Visually verify that the member is still selected (yellow highlighted). If it is not highlighted, select the member again.
-
Change the insulation specification and encasement as needed for the second type of fireproofing that you want to place on the member.
-
Define the fireproofing setbacks for the second type using the Reference 1, Distance 1, Reference 2, and Distance 2 boxes.
-
Click Accept .
-
Verify the fireproofing is where you want it on the member. Adjust the setback properties if needed to keep it from overlapping the first fireproofing that you placed.
-
Click Finish to place the second fireproofing type.