Vertical corner brace frame connection is using the brace member incorrectly as a supporting member. Change connection to unsupported and then re-select the supporting members. - Intergraph Smart 3D - Troubleshooting - Hexagon

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
13.1

Meaning: An attempt is being made to also provide the corner brace as a supporting member, resulting in the improper placement of the corner brace. This error is an internal software failure where the calling software did not properly call the frame connection with its required inputs.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select By Rule from the Connection box on the ribbon.

  6. Redefine the end location of the brace by selecting the frame connection of the supporting beam.