Upgrade Cases - Intergraph Smart 3D - Installation & Upgrade

Intergraph Smart 3D Upgrading from 2018 to 14 Update 6

ft:locale
en-US
Product
Intergraph Smart 3D
Subproduct
Upgrade Guide
Search by Category
Installation & Upgrade
Smart 3D Version
12 (2018)
Platform
On-premises

For version 14 Update 6, the platform requirements have changed for servers and clients. Therefore, you must back up the version 2018 Smart 3D configuration, and then restore it using a client/server configuration that has the new platform requirements for version 14 Update 6. The same basic workflow will apply for each case listed below. In the course of describing the details of each major step, this document takes into consideration four possible upgrade scenarios, or cases, with each requiring a slightly different workflow. Before beginning the upgrade process, select the case that applies to your situation and follow the workflow for the applicable case.

Update Cases MASTER GRAPHIC

Figure 1: Upgrade Considerations from Smart 3D 2018 to Smart 3D 14 Update 6

  • Case A. In-place upgrade of entire 2018 Smart 3D configuration to 14 Update 6 on the same server.

    SHARED Tip This case is not available when upgrading from 2018 to 14 Update 6.

  • Case B. Moving (relocating) databases and upgrading them on another server.

    SHARED Tip This is the most common procedure used for version 14 Update 6 upgrades due to platform requirement changes.

    This is common for cases where all Models and Catalogs associated with the Site are moved and upgraded, or when some of the Models are moved to another server and upgraded while others in the Site remain on the 2018 original server. When Smart 3D configurations from one Site are relocated and upgraded to another server, the SharedContent (Symbols) folder must also be copied and upgraded to the new server or location.

  • Case C. Restoring archived databases and upgrading them with only 14 Update 6 software.

    This case deals with archived backups of the 2018 Smart 3D configurations that are restored in a location where 2018 is not available. In addition to the full database backup, a corresponding backup of the SharedContent (Symbols) folder is required.

  • Case D. Coexistence of 2018 and 14 Update 6 Smart 3D configurations on the same server.

    SHARED Tip This case is not available when upgrading from 2018 to 14 Update 6.

  • In all cases, when one SharedContent (Symbols) folder is shared by multiple Smart 3D configurations that will be separated during an upgrade process (some Models are upgraded to 14 Update 6, while others remain on a previous release), the SharedContent (Symbols) folder must be copied and upgraded with the upgraded Smart 3D configurations.

The SharedContent (Symbols) folder cannot be shared by Models using different versions of Smart 3D. Therefore, the upgraded Smart 3D configuration must use its own copy of the SharedContent (Symbols) folder, while the original Symbols or SharedContent folder stays in 2018.

  • In all cases, ensure that you are pointing to the SharedContent (Symbols) folder for the version to which you will upgrade your model.

  • Your upgrade of the Smart 3D configuration uses the content on your symbol share, and that content must be updated BEFORE migrating the model to the target version.