Meaning: The software could not update the approved hole because the hole is not in Working status.

Recovery:

  1. Select the hole in error.

  2. In the Properties View, select Working from the Status list.

  3. Click Synchronize out of date occurrences in workspace Refresh on the Window Tab.

    Synchronize Workspace with Catalog Dialog displays.

  4. Select the object in error, and then click Update.