Meaning: The centerline frame connection expects two input objects: a supported member and a centerline supporting member. This error is an internal software failure where not all the inputs were provided to the centerline connection.

Recovery:

  1. Select the frame connection in error.

  2. Select More from the Connection box in the Properties View.

  3. Click Centerline in the tree view.

  4. Select the centerline frame connection to use.

  5. Redefine the end location of the member.