This object is not synchronized with the symbol definition - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3Dx Help

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13

Meaning: You can edit a symbol definition after you place occurrences of that symbol. For example, you could place a pump symbol and then later edit the VisualBasic code that defines the geometry of the pump. Synchronize Model with Catalog in Project Management brings the model into agreement with the current symbol definition. When you run this command, you can choose to mark the occurrences, update the occurrences, or both. If you choose to only mark the occurrences, Smart 3Dx displays the out-of-date occurrences with this message in the To Do List after the command finishes.

Recovery:

  1. Click Synchronize out of date occurrences in workspace Refresh on the Window Tab.

    Synchronize Workspace with Catalog Dialog displays.

  2. Select the object in error, and then click Update.

    The software updates the object and removes it from the To Do List.

-OR-

  1. Start Project Management.

  2. Click Tools > Synchronize Model with Catalog.

  3. Select the option to update the out-of-date occurrences. For more information, see Synchronize Model with Catalog in the Project Management User's Guide.