Create a Transfer Switch - Intergraph Smart Electrical - Help - Hexagon

Intergraph Smart Electrical Help

Language
English
Product
Intergraph Smart Electrical
Search by Category
Help
Smart Electrical Version
10
  1. In the Electrical Index, expand the folder hierarchy Electrical Equipment > Power Distribution Equipment > Power Distribution Boards > Transfer Switches folder.

  2. Right-click the Transfer Switches folder, and on the shortcut menu, select New Transfer Switch.

    The software creates a PDB, a bus, two incomers, and a feeder. The Equipment Type property for the PDB is set as Transfer Switch.

  3. Select one of the incomers.

  4. Right-click the incomer and on the shortcut menu, select Common Properties.

  5. On the Circuit Common Properties dialog, select a value for the Circuit Mode property: Connected or Disconnected. When you select a circuit mode value Connected for a transfer switch incomer, the value for the second incomer circuit mode automatically changes to Disconnected. You can set either both incomers or just one incomer to be disconnected.

  6. Specify values for the other incomer properties as you require.

  7. Close the dialog and in the Electrical Engineer, connect items to the feeder and incomer branches as you require.

If the parent folder contains custom folders, the created item is placed in the root folder. If the items properties match the filter properties of a custom folder a copy of the item is also placed in the custom folder. Refreshing or closing and re- opening Smart Electrical moves the item from the root folder to the All Items folder.