ETAP - Smart Electrical Mapped Items - Intergraph Smart Electrical - Help - Hexagon

Intergraph Smart Electrical Help

Language
English
Product
Intergraph Smart Electrical
Search by Category
Help
Smart Electrical Version
10

Smart Electrical is shipped with a fixed default mapping of ETAP elements and Smart Electrical equipment. The table below shows this default mapping.

Note that in cases where the mapping is "many-to-one", you must define the type by specifying the identifier that you select from the Equipment Type Identifier select list (shown here in SEL Equipment Type Identifier column).

ETAP Element

Smart Electrical

SEL Equipment Type Identifier

Battery

Battery bank

-

Busduct

Busway

Busduct

AC Bus

Bus

-

DC Bus

Bus

DC Bus

Bus (see note below)

Local panel

-

Bus (see note below)

Junction box

-

AC Cable

Cable

-

DC Cable

Cable

DC Cable

Capacitor

Capacitor

-

Charger

Battery charger

-

Contactor (ContactorType = Contactor)

Contactor

-

Contactor (ContactorType = Starter)

Starter

-

Current transformer

Current transformer

-

Fuse

Fuse

-

DC Circuit breaker

Circuit breaker

DC Circuit breaker

DC Converter

Other converting equipment

DC Converter

DC Fuse

Fuse

DC Fuse

DC Impedance

Busway

DC Impedance

DC Lumped load

Other electrical equipment

DC Lumped load

Grounding adapter

Other disconnect electrical equipment

Grounding adapter

HVCB

Circuit breaker

High Voltage CB

HVDC transmission link

Busway

HVDC transmission link

LVCB

Circuit breaker

Low Voltage CB

In-line overload relay

Overload relay

In-line overload relay

Impedance

Busway

-

Induction motor

Generator

Induction Generator

Inverter (see the note below for more details)

Other converting equipment

Inverter

Lumped load

Other electrical equipment

Lumped load

Induction motor

Motor

-

DC Machine

Motor

DC Motor

DC Motor

Motor

DC Motor

MG Set

Other electrical equipment

MG Set

Motorized Valve

Motor

Motorized Valve

Overload heater

Overload relay

-

Panel

Other electrical equipment

Panel

Photo voltaic array

Offsite power

Photo voltaic array

DC Photo voltaic array

Offsite power

DC Photo voltaic array

Potential transformer (see the note below for more details)

Potential transformer

-

Power grid

Offsite power

-

Reactor

Current limiting reactor

-

Recloser

Circuit breaker

Recloser

Single throw switch

Disconnect switch

-

DC Single throw switch

Disconnect switch

DC Single throw switch

Static load (Load type = Resistor)

Resistor

-

DC Static load (Load type = Resistor)

Resistor

DC Resistor

Static load (Load type = Heater)

Heater

DC Static load (Load type = Heater)

Heater

DC Heater

Static load (Load type = Trace)

Heat trace

-

DC Static load (Load type = Trace)

Heat trace

DC Heat Trace

Static load (Load type = Lighting)

Lighting fixture

-

DC Static load (Load type = Lighting)

Lighting fixture

DC Lighting fixture

Static load (Load type = Socket outlet)

Socket outlet

-

DC Static load (Load type = Socket outlet)

Socket outlet

DC Socket outlet

Static load (Load type = Welding outlet)

Welding outlet

-

DC Static load (Load type = Welding outlet)

Welding outlet

DC Welding outlet

Static load (Load type = Cabinet)

Cabinet

-

DC Static load (Load type = Cabinet)

Cabinet

DC Cabinet

Static load (Load type = Instrument)

Instrument

-

DC Static load (Load type = Instrument)

Instrument

DC Instrument

Static load (Load type = Other)

Other electrical equipment

Special Electrical Equipment

DC Static Load (Load type = Other)

Other electrical equipment

DC Special Electrical Equipment

SVC

Other electrical equipment

SVC

Synchronous motor

Motor

Synchronous motor

Synchronous Generator

Generator

-

Three-winding transformer

Three-winding transformer

-

Two-winding transformer

Two-winding transformer

-

Transmission line

Busway

Transmission line

Variable frequency drive

Variable frequency drive

-

Uninterruptible power supply

Uninterruptible power supply

-

Inverters

ETAP inverters are published to Smart Electrical as other converting equipment items. Therefore, when retrieving an inverter to Smart Electrical or publishing other converting equipment items that emulate inverters, make sure that you do the following:

  • The other converting equipment item that emulates an inverter must be connected to a DC power supply and its AC/DC power supply flag must be set to DC.

Junction Boxes

When publishing junction boxes from Smart Electrical to ETAP, ETAP retrieves these items as bus nodes. When ETAP users publish this bus back to Smart Electrical, it is retrieved as a junction box and its circuit is retrieved as a panel circuit.

Local Panels and Their Panel Circuits

When exporting a local panel with or without its panel circuit to ETAP, it is retrieved as a bus. When ETAP users publish this bus back to Smart Electrical, it is retrieved as a local panel and the circuit is retrieved as a panel circuit.

Potential Transformers

There are special rules when publishing and retrieving potential transformers.

Publishing Potential Transformers to ETAP

  • Potential transformers that function as metering equipment are not published.

  • A potential transformer created in a feeder or coupler circuit is published with the bus functioning as the power source of the potential transformer. In ETAP, the potential transformer is retrieved connected below the bus.

  • Stand-alone potential transformers are published connected to their equipment as they exist in the electrical flow.

Retrieving Potential Transformers from ETAP

  • If a potential transformer is connected upstream to a bus and a power source, it is retrieved as a circuit internal of an incomer which is connected to the bus.

  • If a potential transformer is connected under a bus, it is retrieved as a circuit internal of a feeder which is connected to the bus.

  • If a potential transformer is connected to one of the ends of a bus, it is retrieved as a circuit internal of an additional feeder which is connected to the bus.

Unsupported Items

A number of items are not supported by the ETAP - Smart Electrical interface. Publishing an unsupported item can have the following possible results:

  • Items could be skipped or ignored in the importing application. After exporting these items back to the original application, they may be deleted or become disconnected or dissociated from their related items.

  • Inability to synchronize or update data.

  • Unexpected behavior.

Unsupported ETAP Elements

The following ETAP elements are not supported by the ETAP - Smart Electrical interface:

  • Instrumentation

  • Multi-function relays

  • Wind turbine generator

  • Double through switches

Unsupported Smart Instrumentation

The following Smart Electrical items are not supported by the ETAP - Smart Electrical interface:

  • Metering equipment (except for current transformers and potential transformers)

  • Other disconnect equipment

  • Control stations (not exported at all)

  • Circuits (not exported at all)

  • Cells (not exported at all)

  • Power distribution boards (not exported at all)

Synchronizing Select List Items

Make sure that the required ETAP drop-down list items are fully synchronized with Smart Electrical select list items. If an ETAP drop-down list item does not exist in Smart Electrical, add it to an appropriate select list in Data Dictionary Manager. For details, see the Data Manager Dictionary Documentation. Mapping of Smart Electrical select list items is done in ETAP. For further information, see the appropriate ETAP documentation.