This procedure explains how to synchronize glands on a number of plant cables with the glands on a specific reference cable.

  1. On the Smart Electrical menu bar, select Actions > Cables >Synchronize Gland Associations.

  2. On the Synchronize Gland Associations dialog, set filter criteria that determine which cables are displayed in the Cable data section.

    You must select an appropriate reference cable whose glands will be synchronized with all the selected plant cables. The Show Cable Data button remains unavailable until you select a reference cable.

  3. Under Synchronize, select one of the following options that determines the side of the cables on which you want to synchronize the glands with the glands on the associated reference cables:

    • Glands on both cable sides — Synchronizes the glands on both sides of the selected cables.

    • Glands on the "To" cable sides — Synchronizes the glands on the "To" side of the selected cables.

    • Glands on the "From" cable sides — Synchronizes the glands on the "From" side of the selected cables.

  4. Select the Show Cable Data button to populate the Cable data section with all the plant cables that comply with filter condition that you have set and whose glands are different from the glands on the associated reference cables.

    This button is available only after selecting a reference cable in the Filter criteria group box and the glands on that reference cable is inconsistent with glands on the selected plant cables.

  5. In the Cable data section, select the cables that you want to be included in the synchronization process.

    Make your cable selection as follows:

    • To select a single cable, select the check box beside the required cable in the data window.

    • To select all the cables in the data window, select the Select cables check box below the data window.

    • To clear the selection of all the cables, select the Select cables arrow and select None.

    • To select all the cables that do not have any glands, select All cables without glands.

    • To select all the cables whose glands are different from the glands on their associated reference cables, select All cables with different glands.

  6. Select OK to start the synchronization process.