12

If you modify properties on the Rights tab, you must execute the Refresh Users command to properly update the site administrator group and plant structure roles.

Category

Options and Descriptions

Catalog

None prevents users from accessing Catalog Manager.

Read-Only allows users to view symbols in Catalog Manager, but not make changes.

Full Control allows users to create new symbols and edit existing symbols.

Plant Filters

None prevents users from accessing Filter Manager.

Read-Only allows users to view existing filter definitions, but not make changes.

Full Control allows users to create new filters and edit existing filters.

Display sets

Controls the ability to view, edit, and define plant display sets.

None prevents users from accessing display sets.

Read-Only allows users to view and apply existing display sets, but not make changes. This option also allows users to copy plant display sets to the My Display Sets folder.

Full Control allows users to apply, create, edit, and delete plant display sets.

  • The options affect plant display sets only. There are no restrictions for display sets under the My Display Sets folder, regardless of the option selected.

  • None allows users to clear a previously-applied plant display set.

  • Full Control is disabled for Workshare satellites.

Plant Reports

None prevents users from viewing or accessing the plant reports.

Read-Only allows users to view existing report definitions, but not make changes.

Full Control allows users to create new plant reports and edit existing reports.

Rules

None prevents users from accessing Rule Manager.

Read-Only allows users to view existing rule definitions, but not make changes.

Full Control allows users to create new rules and edit existing rule definitions.

Data Dictionary
(These settings affect the Update Select List command.)

None prevents users from accessing the Tools > Update Select List command.

Read-Only prevents users from accessing the Tools > Update Select List command.

Modify Select Entry allows users to add and edit select lists on the Update Select List dialog.

Full Control allows users to add and edit select lists on the Update Select List dialog.

Options

None prevents users from accessing Options Manager.

Read-Only allows users to view Options settings, but not make any changes.

Modify Settings allows users to view Options settings and make changes.

Full Control allows users to add options and edit existing options.

Electrical Items Data

None prevents users from viewing or accessing electrical equipment items in the Electrical Index.

Read-Only allows users to view electrical equipment items in the Electrical Index. Users are not allowed to make any changes or create new electrical equipment items in the Electrical Index.

Modify Settings allows users to create and edit electrical equipment items in the Electrical Index. Users are not allowed to delete electrical equipment items in the Electrical Index.

Full Control allows users to create, modify, and delete electrical equipment items in the Electrical Index.

Power Distribution Boards and Internals (Index)

None prevents users from viewing or accessing PDB items and their internals in the Electrical Index.

Read-Only allows users to view PDB items and their internals in the Electrical Index. Users are not allowed to make any changes or create new PDB items or their internals in the Electrical Index.

Modify Settings allows users to create and edit PDB items and their internals in the Electrical Index. Users are not allowed to delete PDB items and their internals in the Electrical Index.

Full Control allows users to create, modify, and delete PDB items and their internals in the Electrical Index.

Wiring Equipment

None prevents users from viewing or accessing wiring equipment items in the Electrical Index.

Read-Only allows users to view wiring equipment items in the Electrical Index. Users are not allowed to make any changes or create new wiring equipment items in the Electrical Index.

Modify Settings allows users to create and edit wiring equipment items in the Electrical Index. Users are not allowed to delete wiring equipment items in the Electrical Index.

Full Control allows users to create, modify, and delete wiring equipment items in the Electrical Index.

Cable Sizing

None prevents users from viewing sizing data and performing cable sizing for single cables or multiple cables in batch mode.

Read-Only allows users to view cable sizing data on the Sizing Data tab of the Cable Common Properties dialog and on the Batch Size Cables dialog.

Full Control allows users to perform cable sizing for single cables on the Sizing Data tab of the Cable Common Properties dialog and on the Batch Size Cables dialog for multiple cables.

Cable Replace

None prevents users from replacing multiple cables in batch mode.

Full Control allows users to replace multiple cables in batch mode.

Single Line Diagram Drawings (Index)

None prevents users from viewing or generating PDB-based single line diagrams.

Read-Only allows users to open and view PDB-based single line diagrams in the Electrical Index. Users are not allowed to edit or generate new PDB-based single line diagrams in the Electrical Index.

Modify Settings allows users to generate, edit, and save PDB-based single line diagrams in the Electrical Index. Users are not allowed to delete PDB-based single line diagrams in the Electrical Index.

Full Control allows users to generate, modify, and delete PDB-based single line diagrams in the Electrical Index.

Single Line Diagram Generation

None prevents users from viewing or generating single line diagrams from the Electrical Engineer.

Read-Only allows users to open and view single line diagrams from the Electrical Engineer. Users are not allowed to edit or generate new single line diagrams from the Electrical Engineer.

Modify Settings allows users to generate, edit, and save single line diagrams from the Electrical Engineer. Users are not allowed to delete single line diagrams that were generated from the Electrical Engineer.

Full Control allows users to generate, modify, and delete single line diagrams that were generated from the Electrical Engineer.

Redlining

None prevents users from turning on the redlining feature.

Full Control allows users to turn on or off the redlining feature.

Schematic Drawings (Index)

None prevents users from opening, viewing, or generating any drawings from Documents folder in the Electrical Index.

Read-Only allows users to open and view the drawings in the Documents folder of the Electrical Index. Users are not allowed to edit or generate new drawings from the Electrical Index.

Modify Settings allows users to open, edit, and save the drawings in the Documents folder of the Electrical Index. Users are not allowed to delete any drawings from the Documents folder of the Electrical Index.

Full Control allows users to generate, modify, and delete the drawings from the Documents folder of the Electrical Index.

Schematic Drawing Generation

None prevents users from viewing or generating schematic drawings in the Electrical Index.

Read-Only allows users to open and view schematic drawings in the Electrical Index. Users are not allowed to edit or generate new schematic drawings in the Electrical Index.

Modify Settings allows users to generate, edit, and save schematic drawings in the Electrical Index. Users are not allowed to delete schematic drawings in the Electrical Index.

Full Control allows users to generate, modify, and delete schematic drawings in the Electrical Index.

Apply Options

Enables or disables the available Apply Options features. Select to enable a feature; clear to disable. The following features can be enabled or disabled:

  • Profile

  • Circuit

  • Control Station

  • Lookup

  • Schematic

  • I/O Set

Association

Among Items allows users to enable or disable the following features:

  • Perform Batch Load Association.

  • Use Parallel Equipment Assistant.

  • Drag items in and to the Electrical Index and Electrical Engineer.

Select to enable the features; clear to disable.

External Documents allows users to enable or disable associating and dissociating external documents. Select the to enable; clear to disable.

Reference Documents

None prevents users from defining a reference to a document. Also, when associating a document, users cannot associate a document with a plant item.

Read-Only allows users to see the list of the associated documents on the Define Document Reference dialog. Users are not allowed to create a new reference or dissociate a document.

Modify Settings allows users to add new references on the Define Document Reference dialog but not dissociate any documents from plant items.

Full Control allows users to add or remove a reference to a document in the Define Document Reference dialog.

Templates

None prevents users from viewing Smart Electrical templates.

Read-Only allows users to view template definitions, but not make any changes.

Modify Settings allows users to edit existing templates.

Full Control allows users to create new and edit existing templates.

Reference Data Explorer - Cables

None prevents users from seeing any reference cable items in the Reference Data Explorer.

Read-Only allows users to see reference cable items in the Reference Data Explorer and view reference cable properties, but not make any changes.

Modify Settings allows users to edit the properties of existing reference cables. Users are not allowed to create or delete reference cables.

Full Control allows users to create, edit, and delete reference cables.

Reference Data Explorer - Lookup Tables

None prevents users from seeing any lookup table items in the Reference Data Explorer.

Read-Only allows users to see lookup table items in the Reference Data Explorer and view lookup table properties, but not make any changes.

Modify Settings allows users to edit the properties of existing reference lookup tables. Users are not allowed to create or delete reference lookup tables.

Full Control allows users to create, edit, and delete reference lookup tables.

Reference Data Explorer - Other Categories

None prevents users from seeing any equipment items in appropriate Reference Data Explorer folders.

Read-Only allows users to see all reference equipment items in appropriate Reference Data Explorer folders and view the equipment items properties, but not make any changes.

Modify Settings allows users to edit the properties of existing reference equipment items. Users are not allowed to create or delete reference equipment items.

Full Control allows users to create, edit, and delete reference equipment items.

Tabular Editor Layouts

None prevents users from accessing Tabular Editor layouts.

Full Control allows users to create and manage Tabular Editor layouts.

Electrical Engineer

None prevents users from accessing the Electrical Engineer.

Full Control allows users to use all Electrical Engineer features. Full Control access is required to copy items from Electrical Engineer from another plant.

Import Manager

None prevents users from opening Import Manager.

Full Control allows users to open and work with Import Manager.

Integration

Publish enables or disables document publishing. Select to enable; clear to disable.

Retrieve enables or disables document retrieval. Select the to enable; clear to disable.

Registered Reports

None prevents users from registering internal documents.

Read-Only allows users only to open and view the registered reports.

Modify Settings allows users to create and edit registered reports using the Common Properties dialog, set revisions.

Full Control allows users to modify and delete registered reports.

Project Management
(As-Built)

None prevents users from accessing the Project Management table in the As-Built.

Full Control allows users to use the Project Management table in the As-Built.

Project Management
(Projects)

None prevents users from accessing the Project Management table in projects.

Full Control allows users to use the Project Management table in projects.

Apply Naming Convention

Select Enable to allow users to apply a naming convention to Smart Electrical item tags. Clear to disable this option.

This setting has no effect on the ability to define naming conventions in Options Manager.

Wiring Diagrams

None prevents users from viewing wiring diagrams.

Read-Only allows users to view wiring diagrams, but not make any editing changes or revisions.

Modify Settings allows users to edit (place equipment and terminal strips, cables and wires and perform terminations), revise, and save existing wiring diagrams.

Full Control allows users to create new wiring diagrams and to edit, revise, save, and delete existing wiring diagrams.

Cable Block Diagrams

None prevents users from viewing cable block diagrams.

Read-Only allows users to view cable block diagrams, but not make any editing changes or revisions.

Modify Settings allows users to edit (place reference and project equipment and cables, perform connections, and so forth), revise, and save existing cable block diagrams, and set filters for common properties.

Full Control allows users to create new cable block diagrams and to edit, revise, save, and delete existing cable block diagrams.

PDB Layouts

None prevents users from viewing PDB layouts.

Read-Only allows users to view PDB layouts, but not make any editing changes or revisions.

Modify Settings allows users to edit, revise, and save existing PDB layouts.

Full Control allows users to create new PDB layouts and to edit, revise, save, and delete existing PDB layouts.

Miscellaneous Drawings

None prevents users from viewing miscellaneous drawings.

Read-Only allows users to view miscellaneous drawings, but not make any editing changes or revisions.

Modify Settings allows users to edit, revise, and save existing miscellaneous drawings.

Full Control allows users to create, edit, revise, save, and delete existing miscellaneous drawings.

Bus Load Summary Calculation Method

None prevents users from selecting the options under Calculation method on the Load Summaries and Reports tab of the Preferences dialog.

Full Control allows users to modify the preferences for load summary calculations.

Switch Active Operating Case

None prevents users from switching the operating case.

Full Control allows users to select a specific operating case and make it the active operating case for the plant.

Display Sets

Controls the ability to view, edit, and define plant display sets.

None prevents users from accessing display sets.

Read-Only allows users to view and apply existing display sets, but not make changes. This option also allows users to copy plant display sets to the My Display Sets folder.

Full Control allows users to apply, create, edit, and delete plant display sets.

  • The options affect plant display sets only. There are no restrictions for display sets under the My Display Sets folder, regardless of the option selected.

  • None allows users to clear a previously-applied plant display set.