This procedure explains how to edit the properties of a routing section.

  1. In the Wiring Module window, click Tables> Cable Routing > Routing Sections.

  2. On the Routing Sections dialog box, filter the routing sections by selecting Trunk or Building, or accept the default All.

  3. Highlight a routing section and click Properties.

  4. On the Routing Section Properties dialog box, you have the following options:

    • To modify the routing section name.

    • To modify the length (unless the cable assigned to this section is on a locked drum).

    • To change the section category, from the Routing category list, if the section is not in use.

    • For routing category Trunk, to select a width for each position from the Position and widths grid (unless the cable assigned to this section is on a locked drum).

  5. Click OK to save your changes and close the Routing Section Properties dialog box.