Workflow implementation begins when the instrument engineer who is going to work on instrument tags determines whether those tags require process data. Next, those tags that do require process data are assigned to a process engineer for process data input. On completion of the data input, the tags are reassigned to the instrument engineer for instrument data input.

Enter Initial Instrument Data

  1. Log on to Smart Instrumentation as a user in the Instrument group.

  2. In the Instrument Index module, create the instrument tags as you require and enter appropriate data.

  3. Open the EDE View you created that contains the items that require process data.

    SHARED Tip If the EDE is already open, select PPM All Outputs Graphic on the EDE Actions toolbar, new items become visible.

  4. In the Process Data Status field, select the required status of each instrument tag you will be editing as follows:

    1. For instrument tags that require process data, select status: Process Data Required. These tags will be available for the process engineer in the Process Data and Calculation modules.

    2. For instrument tags that do not require process data, select status: Process Data not Required.

Enter Process Data for Instrument Tags

  1. Log on to Smart Instrumentation as a user in the Process group.

  2. In the Process Data module, select Edit > Open Process Data > Instrument Instrument icon 16bit.

  3. In the Enter Tag Number dialog, do one of the following:

    • If known, type the tag number for the instrument you want to add process data.

    • Select Find, and from the Open Process Data - Find Items dialog, select the required instrument, and then select OK.

  4. On the Enter Tag Number dialog, select OK.

  5. On the Process Data dialog, select a fluid state and select OK.

  6. On the Process Data sheet, enter the required process data and select OK.

  7. Select Actions > Save Process Data Save Icon 16bit.

  8. In the Select a New Process Data Status dialog, select Release to Instrument, and select OK.

Enter Additional Instrument Data

  1. Log on to Smart Instrumentation as a user in the Instrument group.

  2. Open the EDE View you created that contains the items to which you added process data.

  3. For each tag for which you want to edit instrument data, change the value under Process Data Status from Release to Instrument to Lock out from Process.

  4. In the Instrument Index module, open each tag individually and enter the required instrument data.