The following commands are used when working in the Instrument Index module.
Edit > Tag Numbers > New Tag Number
Adds a new tag to the current domain
Edit > Tag Numbers > Tag Number Properties
Edits the properties of a tag number that you select in the Enter Tag Number dialog.
Edit > Tag Numbers > Duplicate Tag Numbers
Duplicates a tag number that you select in the Enter Tag Number dialog.
Edit > Tag Numbers > Delete Tag Numbers
Deletes a tag number that you select in the Enter Tag Number dialog.
Edit > Tag Numbers > Move Tag Number
Moves a tag number that you select in the Enter Tag Number dialog to another <unit> <area> or <plant>.
Edit > Loop Numbers > New Loop Number
Creates a new loop number.
Edit > Loop Numbers > Loop Number Properties
Edits the properties of a loop that you select in the Enter Loop Number dialog.
Edit > Loop Numbers > Duplicate Loop Number
Creates a new loop by duplicating the properties of an existing loop.
Edit > Loop Numbers > Delete Loop Number
Deletes a loop number that you enter in the Enter Loop Number dialog.
Edit > Loop Numbers > Move Loop Number
Moves a loop number that you select in the Enter Loop Number dialog to another <unit> <area> or <plant>.
Edit > Loop Numbers > Rename Multiple Loop Numbers
Renames a loop number.
Reports > All Tag Numbers
Opens the Report Selection Options dialog for creating a tag summary report.
Reports > Available Tag Numeric Segments
Opens the Available Tag Numeric Segments dialog to create a report of all the unused numeric segments of tag numbers in the current <unit> or <plant>.
Reports > Loop Tag Numbers
Creates a report of loop numbers and their associated tags.
Reports > Loop Summary
Opens the Report Selection Options dialog for creating a loop summary report.
Reports > Tables > Standard Instrument Type List
Creates an Instrument Type Report.
Reports > Tables > Detailed Instrument Type List
Creates a Detailed Instrument List Type Report.
Reports > Tables > Instrument Statuses
Creates an Instrument Status Report.
Reports > Tables > I/O Types
Creates an I/O Types Report.
Reports > Tables > Instrument Locations
Creates an Instrument Location Report.
Reports > Tables > Equipment Type
Creates an Equipment Type Report.
Reports > Tables > Equipment
Creates an Equipment Report.
Reports > Tables > P&ID Drawing References
Creates a P&ID Drawing References Report.
Reports > Tables > Line Type
Creates a Line Type Report.
Reports > Tables > Lines
Creates a Lines Report.
Reports > Tables > Instrument Criticality
Creates an Instrument Criticality Report.
Reports > Tables > Instrument Manufacturers
Creates an Instrument Manufacturers Report.
Reports > Tables > Instrument Models
Creates an Instrument Models Report.
Reports > Tables > Loop Measured Variables
Creates a Loop Measured Variables report.
Reports > Tables > Function Blocks
Creates a Function Blocks Report.
Reports > Electrical Equipment Tables > Associated Electrical Equipment
Creates an Associated Electrical Equipment Report.
Reports > Electrical Equipment Tables > Associated Electrical Equipment & Types
Creates an Associated Electrical Equipment and Types Report.
Reports > Electrical Equipment Tables > Circuits
Creates a Circuits Report.
Reports > Telecom Devices
Creates a Telecom Devices Report.
Reports > Telecom Tables > Standard Telecom Type List
Creates a Telecom Type Report.
Reports > Telecom Tables > Detailed Telecom Type List
Creates a Telecom Type List Report.
Reports > Telecom Tables > Telecom Line Numbers
Creates a Telecom Line Numbers Report.
Reports > Telecom Tables > Telecom Field Equipment
Creates a Telecom Field Equipment Report.
Reports > Telecom Tables > Telecom Signal Levels
Creates a Telecom Signal Levels Report.
Reports > Power Supply Tables > Rated Voltage
Creates a Rated Voltage Report.
Reports > Power Supply Tables > Frequency
Creates a Frequency Report.
Reports > Power Supply Tables > Number of Phases
Creates a Number of Phases Report.
Reports > Power Supply Tables > Operating Modes
Creates an Operating Modes Report.
Actions > Associate
Opens the Associate Tag Number dialog to associate a selected loop with tag numbers.
Tables > Instrument Types
Opens the Instrument Types dialog.
Tables > General Process Function Sub-Categories
Opens the General Process Function Sub-Categories dialog for defining a sub-category for the general process function.
Tables > Instrument Statuses
Opens the Instrument Statuses dialog for maintaining the Status drop-down list.
Tables > I/O Types
Opens the I/O Types dialog for maintaining the contents of the I/O Types list.
Tables > Instrument Locations
Opens the Instrument Locations dialog for specifying general or specific instrument locations within the <plant>.
Tables > Equipment
Opens the Equipment dialog for categorizing equipment that your instruments are installed on.
Tables > P&ID Drawing References
Opens the P&ID Drawing References dialog.
Tables > Lines
Opens the Lines dialog for categorizing and modifying line data.
Tables > Tag Categories
Opens the Tag Category dialog where you add, delete, or edit tag categories that you then assign to selected tags in the Associate Categories and Criticality dialog.
Tables > Instrument Criticality
Opens the Instrument Criticality dialog enabling you to customize instrument criticality data.
Tables > Instrument Certification
Opens the Instrument Certification supporting table that holds certification for instruments that are certified for hazardous environments.
Tables > Instrument Manufacturers
Opens the Instrument Manufacturers supporting table.
Tables > Instrument Models
Opens the Instrument Models dialog where you store instrument model data.
Tables > Function blocks
Opens the Function blocks dialog where you can add, delete, and modify user-defined function blocks.
Tables > Intrinsically Safe Circuit Types
Opens the Intrinsically Safe Circuit Types dialog.
Tables > Loop Measured Variables
Opens the Loop Measured Variables dialog allowing you to enter or modify the loop process variable identifier that is used in the loop naming conventions.
Tables > Loop Types
Opens the Loop Types supporting table.
Tables > Loop Functions
Opens the Loop Functions dialog allowing you to enter or modify the loop function identifier that is used in loop naming conventions.
Tables > Electrical Equipment > Associated Electrical Equipment
Opens the Associated Electrical Equipment Types dialog. This allows you to view equipment tags that are associated with signals that are defined in Smart Electrical and the equipment type to which each signal belongs.
Tables > Electrical Equipment > Associated Electrical Equipment Types
Opens the Associated Electrical Equipment Types dialog. This shows all the available associated electrical equipment types to which Smart Electrical signals can belong.
Tables > Electrical Equipment > Circuits
Opens the Electrical Equipment supporting table. This supporting table holds circuit values that appear in the Circuit list on the Electrical tab of the Tag Number Properties dialog.
Tables > Telecom > Telecom Device Types
Opens the Telecom Device Types dialog. You use this dialog to create and manage telecom device types.
Tables > Telecom > Telecom Line Numbers
Opens the Telecom Line Numbers dialog. You use this dialog to maintain the contents of the Telecom line list when creating a telecom field device.
Tables > Telecom > Telecom Field Equipment
Opens the Telecom Field Equipment dialog. You use this dialog to maintain the contents of the Field Equipment drop-down list in the Tag Number Properties dialog.
Tables > Telecom > Telecom Signal Levels
Opens the Telecom Signal Levels dialog. You use this dialog to maintain the contents of the Signal Level drop- down list in the Tag Number Properties dialog.
Tables > Power Supply > Rated Voltage
Opens the Rated Voltage supporting table. This shows the rated voltage values that you can use in the Rated voltage list on the Power Supply tab of the Tag Number Properties dialog.
Tables > Power Supply > Frequency
Opens the Frequency supporting table. This shows the frequency values that you can use in the Frequency list on the Power Supply tab of the Tag Number Properties dialog.
Tables > Power Supply > Number of Phases
Opens the Number of Phases supporting table. This shows the number of phase values that you can use in the Number of phases list on the Power Supply tab of the Tag Number Properties dialog.
Tables > Power Supply > Operating Modes
Opens the Operating Modes supporting table. This shows the operating mode values that you can use in the Operating mode list on the Power Supply tab of the Tag Number Properties dialog and the properties dialogs of panels that support power supply.
Tables > Signal Type
Opens the Signal Type dialog that holds signal type values that are used to define HART instrument properties.
Tables > Linearity Types
Opens the Linearity Types dialog that holds linearity type values that are used to define HART instrument properties.