Resolve Grid Line Overlap Problems - Intergraph Smart Instrumentation - Help

Intergraph Smart Instrumentation Help

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Help
Smart Instrumentation Version
13.1
  1. Open the appropriate spec page in InfoMaker. For details, see Open a Form Page in InfoMaker.

  2. In InfoMaker, make sure that lines that intersect near problematic fields do not overshoot. Overshooting occurs when grid lines meet imperfectly, and at least one of the lines extends beyond the meeting point. If overshooting occurs, see Correct Undershooting and Overshooting of Grid Lines.

  3. If there is no overshooting, make sure that you set constant Y1 and Y2 values for all of the objects between the lines. The Y1 value should be several PBUs (PowerBuilder units) greater than the Y values of the line above, and the Y2 value should be several PBUs less than the Y values of the line below.

  4. Import the page back into Smart Instrumentation.

  5. Regenerate the spec page and specification, and save the specification again in Excel format.