  1. In InfoMaker, to define the sp_style.pbl library as your working library, do the following:

    1. Select Tools > Library Painter.

    2. Right-click sp_style.pbl and then select Set as working library.

    SHARED Tip The sp_style.pbl file is a shipped library containing all drop-down data windows of Smart Instrumentation. The file resides in your Smart Instrumentation home folder.

  2. Open the target form page that you saved as a .psr file. For details, see Open a Form Page in InfoMaker.

  3. In the Report window, right-click the target table column that is used as a custom field in the spec page, and then, select Properties.

  4. In the Properties window, select the Edit tab, and then from the Style Type list, select DropDownDW.

  5. Select Always Show Arrow to display in the spec page an arrow box inside the field to indicate that this field is assigned to a drop- down data window or select list.

  6. Select V ScrollBar to display a vertical scroll bar when the drop-down data window contains a long list values.

  7. Beside the DataWindow box, select .

  8. On the Select Report dialog, select a unit of measure drop-down data window you want to assign to the field. For details about the available drop-down data windows that retrieve units of measure, see Drop-Down Data Windows that Retrieve Units of Measure.

  9. From the Display Column list, select uom_code.

  10. From the Data Column list, select uom_code.

  11. Save the .psr file.

  12. Test your drop-down data window assignment in Smart Instrumentation, open the .psr file in the Page Editor, save it as a new regenerated page, assign to a form, and generate a specification based on this form.