This procedure shows you how to create a device panel with a device cable in the Engineering Data Editor's (EDE) Module.
-
In the EDE Explorer, open an EDE View from the Instrument Index folder.
-
Select the required tag numbers.
-
Right-click, and from the shortcut menu, select, Actions > Create Device Panel and Cable.
-
On the Results dialog, view the propagation results, and then select Close.
To make this feature work, you must select the Create wiring check box and choose a reference device panel on the Wiring and Control System tab in the instrument type profile of the selected tag number before you attempt to create a new device panel. You can also select a reference device cable if you want Smart Instrumentation to create device cables with the device panels. For more details, see Define an Instrument Type Profile.