A file named Attributes (or Attributes.txt) contains a list of the source tables where the PDS data is located, some examples of which are shown below.

Table No.

Name

Data Type

Default Value

Units of Measure

App Type(s)

Description

0

system_unique_no

I4

0

0

1

'Occurrence no'

1

propagation_no

I2

0

0

1/1

'Propagation no'

2

company_name

A40

0

0

1

'Company name'

3

plant_name

A40

0

0

1

'Plant name'

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

109

instr_comp_type

C510

1

0

2

'Instr comp type'

Each database table includes a data type code that refers to a file containing a list of fields that belong to the table together with their codes. For example, the data type for table 109, instr_comp_type is C510. This refers to the file LIST.0510, part of which is as follows:

MAX=999

; 0510, Instrument Component Type (999)
   1  ' '
;
      16  'Instrument to Process line'
      17  'Capillary tube'
      18  'Mechanical link'
      19  'Electric signal'
      20  'Electric binary signal'
;
      72  'Control valve'
      78  'Solenoid valve'

This means that the PDS field with code no. 72 will be displayed in Smart Instrumentation with the source name Control Valve.