This option enables you to display and modify the current status of working dimensional data for the selected instrument. Three status stages are available: Preliminary, Design, and Certified. Each change of status results in the revision number being set to 0. Within each status, the revision number (from zero to 99) indicates the progress of the dimensional data handling. An instrument status can be described as a combination of these two parameters: the status of the Working dimensional data and the revision number, for example PRELIMINARY 1 or DESIGN 5.

  • When you modify the data status because of any dimensional data management, you will be able to reset the suspected data flag and mark the data as correct and ready for release to piping.

  • You can select multiple instruments for status modification.

  1. In the Working Data window, highlight the instruments whose working status you want to modify.

  2. Select Actions > Modify Status and Revision.

  3. On the Status tab, select Set status and select the required status from the Status list.

    The list displays the selected status and becomes unavailable until you select Set status again.

  4. Select Raise to next revision to raise the revision number if needed.

  5. Select in the Description text box and type a short status description.

  6. Select the Reset Suspect Flag check box to remove the suspected data status for the current instrument.

  7. Select Save to save your settings.

  8. Select Next or Previous to display the next or previous selected tag number.

  9. Select OK to close this dialog or select the History tab to open the History tab folder.