  1. Start the Instrument Index module.

  2. On the Instrument Index module menu bar Select Tables > Instrument Types.

  3. In the Instrument Types dialog, select a process function type and an instrument type.

  4. Select Profile.

  5. On the Instrument Type Profile dialog, on the General tab, select the Include I/O type check box.

  6. From the Include I/O type list, select one of the following:

    • FieldbusFF Foundation Fieldbus

    • Profibus PA

  7. In the Function Block - Instrument Type Association dialog, to assign a function block to an instrument type, do one of the following:

    • In the Unassociated function blocks data window, select the function block that you want to associate, and Select Associate.

    • Drag the required function block from the Unassociated function blocks data window to the Associated function blocks data window.

  8. If the required function block is not available in the Function Block - Instrument Type Association dialog, add or modify the function blocks in the Function Blocks dialog. For details, see Manage the Function Blocks Supporting Table.

  9. If you customized a given function block in the Function Blocks dialog, do the following as needed:

  10. To set the maximum number of instruments that can be associated with the current function block, in the Associated function blocks data window, under Multiple, type the value.

  11. To set the execution time, under Execution Time, type the time value (in milliseconds).

  12. Select OK.