There are five statuses that relate to tags under Workflow. The following table provides a description of each status and which groups (instrument engineers or process engineers)can set and change the status in the Workflow:
Status |
Description |
Set / Changed by |
---|---|---|
Process Data not Required |
Tags that do not require process data and therefore are not available to the process engineering group. |
Set and changed by instrument engineers. |
Process Data Required |
Tags available for process data entry by the process engineering group (in the Process Data module). |
Set by instrument engineers. Can be changed by process engineers. |
Lock out from Instrument |
Tags marked for editing by the process engineering group and not available to the instrument group. |
Set and changed by process engineers. |
Release to Instrument |
Tags available to the instrument engineering group following release from the process group. |
Set by process engineers. Can be changed by instrument engineers. |
Lock out from Process |
Tags not available to the process engineering group. |
Set and changed by instrument engineers |