Use this procedure to add new pipes to the Pipe Data Library.

  1. In the Process Data Module window, select Edit > Open Process Data > Line Process.

  2. On the Select Line dialog, from the Line type list, select a line type.

  3. Select Properties.

  4. On the Line Properties dialog, from the Pipe standard list, select ANSI, DIN, or ASME DN. This opens the Pipe Data Library dialog.

    In the Default column, Yes indicates a default library item, and No indicates that the item is user-defined.

  5. On the Pipe Data Library dialog, select New.

    SHARED Tip If you want to view details of an item which exists in the Pipe Data Library, highlight that item and select Properties.

  6. On the Library Item Properties (New) dialog, type the pipe data values and select OK.

  7. On the Pipe Data Library dialog, select OK.

  8. On the Line Properties dialog, select OK.

  9. On the Select Line dialog, select OK.