Use this procedure to add new pipes to the Pipe Data Library.
-
In the Process Data Module window, select Edit > Open Process Data > Line .
-
On the Select Line dialog, from the Line type list, select a line type.
-
Select Properties.
-
On the Line Properties dialog, from the Pipe standard list, select ANSI, DIN, or ASME DN. This opens the Pipe Data Library dialog.
In the Default column, Yes indicates a default library item, and No indicates that the item is user-defined.
-
On the Pipe Data Library dialog, select New.
If you want to view details of an item which exists in the Pipe Data Library, highlight that item and select Properties.
-
On the Library Item Properties (New) dialog, type the pipe data values and select OK.
-
On the Pipe Data Library dialog, select OK.
-
On the Line Properties dialog, select OK.
-
On the Select Line dialog, select OK.