The following commands are used when you select Line in the Process Data window. Note that there is variability in the fields displayed, depending on the process function and fluid phase that you select.

Instrument icon 16bit Edit > Open Process Data > Instrument

Open a process data sheet for an instrument.

Process Edit > Open Process Data > Line

Opens a process data sheet for a line.

Edit > Pipe/Orifice Materials

Opens a dialog to enter additional pipe/orifice materials or modify the existing ones.

Edit > Fluid Components

Opens a dialog to maintain the Fluid Components supporting table, which you need to create a Line Components table for a complex analyzer line.

Edit > Line Components

Actions > Enable Case

Opens a dialog to select a case name for the current process data sheet (available only if you have not yet created at least one case for this line).

Actions > Add Case

Add a case to the current line or tag (available only for a multi-case line or tag).

Actions > Delete Case

Delete the active case from the current line or tag (available only for a multi-case line or tag).

Actions > Set as Governing

Sets the current process data case as the Governing case (available only if the current line has at least one case).

Save Icon 16bit Actions > Save Process Data

Save the current process data values (available only if you changed process data since the previous save).

Actions > Recalculate Properties

Recalculate process data for the current line (available only for fluid states water and steam).

Actions > Pipe Data

Opens a dialog where you can select other pipe standard parameters for the current line.

Actions > Report

Generate a process data report for the current instrument.

Actions > Assign Sheet Numbering

Opens a dialog where you assign a number to the current sheet within a process data sheet report.

Options > History Options

Opens a dialog to set process data history indication.

Options > Mark Changes

Marks the changes in the current process data sheet for the dates you selected in the History Options dialog. Enabling this option disables the Compare function available in the print preview.

Options > Automatic Unit Conversion

Converts engineering units of measure.

Options > Calculate Liquid Compressibility

Calculates liquid density using the liquid compressibility factor.

Options > Saturated Steam

Calculates saturated steam temperature in accordance with its pressure (available if you selected Steam from the Fluid state list).