Create a Loop with a Single Instrument Tag - Intergraph Smart Instrumentation - Training - Intergraph Process, Power & Marine Documentation

Intergraph Smart Instrumentation Tutorial

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Training
Smart Instrumentation Version
2018 (12.0)
  1. Close the Domain Explorer.

  2. Click Module > Instrument Index.

  3. In the Instrument Index Module window, on the toolbar, click New Tag new_tag_number_16.

  4. On the New Tag Number dialog box, type tag number 101-PT-201, and click OK.

  5. On the Loop Name dialog box, accept the loop name 101-P-201 and click OK.

  6. On the Loop Number Properties dialog box, click OK.

  7. On the Tag Number Properties dialog box, do the following to create the equipment that you need:

    1. Beside Equipment, click to open the Equipment dialog box.

    2. From the Equipment Type list, select TANK.

    3. Click New to add a new row.

    4. In the Equipment column, type F-102 and click OK.

  8. Click OK.

  9. On the Tag Number Properties dialog box, complete the data entry as shown.

  10. Click OK.

  11. In the Instrument Index Module window, on the toolbar, click Loop Properties icon 16bit (Loop Properties).

  12. On the Enter Loop Number dialog box, click Find.

  13. On the Loop Number Properties - Find Items dialog box, in the Search box, type *P, and press the Enter key to execute the search..

    SHARED Tip The * symbol is a multi-character wildcard which substitutes for any characters that precede or follow the specified character or string.

    The Find Loop dialog box should display the following result:

  14. Select loop 101 P -201 and click OK.

  15. On the Loop Number Properties dialog box, do the following to add a loop function to the Loop function list:

    1. In the Loop service box, type F-102 TOP.

    2. Beside Loop function, click .

    3. On the Loop Functions dialog box, click New to add a new line.

    4. In the Loop Function column, type IA.

    5. In the Description column, type Indication and Alarm.

    6. Click OK.

  16. Clear the Apply equipment to tags check box.

  17. Enter the remaining loop data as shown.

  18. Click OK, and when prompted to edit tag numbers, click No.

  19. Press F7 to open the Domain Explorer.

  20. Expand New Refinery > Crude Area > Crude Unit 1 to displays item folders in Crude Unit 1.

  21. Expand the Loops folder and view loop 101 P-201 and its tag.