Assign Blocks to Instrument Types - Intergraph Smart Instrumentation - Training - Intergraph Process, Power & Marine Documentation

Intergraph Smart Instrumentation Tutorial

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Training
Smart Instrumentation Version
2018 (12.0)
  1. Open the Loop Drawing module by doing one of the following:

    1. On the main toolbar, click Loops icon 16bit.

    2. On the main menu bar, click Modules > Loop Drawings.

  2. Do one of the following:

    • On the Loop Drawings Module window toolbar, click .

    • On the Loop Drawings Module window menu bar, click Actions > Block - Instrument Type Assignment.

  3. On the Block – Instrument Type Assignment dialog box, scroll down the list of instrument types and select FE – D/P TYPE FLOW ELEMENT as shown.

    SHARED Tip This selection will only create associations with those instruments of type FE which are described as D/P Type Flow Element, and not with other FE descriptions.

  4. Click Assign.

  5. On the Assign Block To Instrument Type dialog box, from the Block type list, select Instruments, and then in the data window select Orifice Plate SmartSketch.

  6. Click OK to assign this block to the FE D/P Type Flow Element instrument type.

    The Block – Instrument Type Assignment dialog box should appear with Block: Orifice Plate SmartSketch.

  7. Make other block – instrument type assignments as shown in the following table.

    Instrument Type

    Description

    Block Name

    FT

    D/P Type Flow Transmitter

    Analog Input SmartSketch

    FV

    Control Valve

    Control Valve SmartSketch

    FY

    I/P Transducer

    Analog Output SmartSketch

  8. When done, click Close.