At this stage, it is assumed that you have already created lines 4"-P-1501-11H and 4"-P-1502-11H when defining you instrument index data. Now you are going to create a new line in the Process Data module.
-
To open the Process Data module, do one of the following:
-
On the main toolbar, click .
-
On the Modules menu, click Process Data.
-
-
On the module toolbar, click (Line).
-
On the Select Line dialog box, from the Line Type list, select Utilities.
-
Click New to open the Line Properties dialog box.
-
Define new line 1.5"-S-2001-4C and click OK to return to the Select Line dialog box.
-
On the Select Line dialog box, click OK again to complete the new line creation process.
-
On the Process Data dialog box, from the Fluid state list, select Liquid, and then, click OK.
-
Close the 1.5”-S-2001-4C Process Data Sheet, saving changes if prompted.