  1. In the Domain Explorer, in the Hook-Ups folder, right-click the Control Valve hook-up, and then, on the shortcut menu, click Reports > Generate Hook-Up Drawings.

  2. On the Generate Hook-Up Drawings dialog box, click OK.

  3. When prompted to open the report print preview, click Yes to open the drawing in the Enhanced Report Utility.

  4. Check whether the macros have retrieved the instrument tag numbers and hook-up item properties.

    Hook_28

  5. Close the Enhanced Report Utility.

  6. Generate an enhanced report hook-up drawing for the Flow Instrument hook-up.

  • Only symbols of file type .sym can be used when generating an enhanced hook-up drawing.

  • The Tag list and Associated items list can be dragged to any position on the Enhanced Hook-Up Drawing, but their positions cannot be saved within the drawing, unless the drawing is saved as an external file. Printing the drawing creates the drawing with the lists as displayed in the Enhanced Report Utility.