Clear description of a detail tag if it is the second or higher detail tag.
With this project default (default = N), you can control how the description of the detail tags will be generated when clicking the Split Tag or Split Master Tag buttons.
If ZP_CLR_DSC is set to Y, the description of the new detail tags are generated differently: the first detail tag gets exactly the same description as the master tag itself, and all following detail tags get an empty description (-). Changing back to ZP_CLR_DSC = N, the descriptions of the detail tags are built as usual.
-
Module(s) affected by this setting: C2001, C200102, C2004, C2005, OPI1001, P3027, P5007, P7031, P7062, P7072, P7074, P8011, P8051
-
Default value: N
-
List of Values: N/Y