ZC_MRRAPPR - Intergraph Smart Materials - Version 10.2 - Administration & Configuration - Hexagon

Intergraph Smart Materials Classic Administration (10.2)

Language
English
Product
Intergraph Smart Materials
Subproduct
Classic
Search by Category
Administration & Configuration
Smart Materials/Smart Reference Data Version
10.2

This project default specifies the material receiving report (MRR) approval template.

If an approval template is assigned to ZC_MRRAPPR, MRRs can only be posted if all users in the approval sequence have approved the material receiving report on the A.20.49 Approval Sequence screen. If an approval template is assigned to project default ZC_MRRAPPR and you select the RfA check box, this approval template is copied to the approval sequence of this MRR.

If this project default is not set, you can post the MRR without approval.

  • Module(s) affected by this setting: C2001, C200102, C2003, C2004, C2005

  • Default value: ./.

  • List of Values: A2045 Approval Templates of type MRR