This record type defines exactly one Smart Materials ident. For each of these records, exactly one record will be created in the Smart Materials table M_IDENTS, if all validations succeed.

The specified commodity group must be present on S.10.02 - Commodity Groups, else: Error!

The specified commodity part must be present on S.10.03 – Commodity Parts, else: Error!

The specified commodity code must be present on S.30.01 – Commodity Codes, else: Error!

The commodity group and commodity part must match the commodity code, else: Error!

If either the commodity group or commodity part has been defined in a discipline other than the discipline the user is logged into, a warning message will be written to the import protocol, but processing will continue.

If the specified ident code is already present in the scope of the target project or the product group: Error!

If the combination of commodity code and size 1 - size 5 is already present on S.80.04 - All Idents: Error!

If the project/discipline default ZI_OII_S80 is set to Y, and if the commodity code is of an item type with item rule 'STD' or item rule 'SWT', the combination of commodity code and input 1 – input 5 must be present on S.80.01 – Build New Idents, else: Error!

If the project/discipline default ZI_OII_S80 is set to N, then the check against S.80.01 will not be performed.

If the specified commodity code is of an item type with item rule 'TOM' or item rule 'TWM', the check against S.80.01 will not be performed, either (so no dummy geometric series needs to be assigned to this commodity code in order to import idents); however, the combination of commodity code and size 1 – size 5 still needs to be unique.

If you specify a unit system, it must match a unit system defined on A.10.06 – Unit Systems, else: Error! If you don’t specify a unit system in your file, the project default is used.