Search by Category
Administration & Configuration
Smart Construction Version
8
Smart Materials/Smart Reference Data Version
10.1

If this check box is selected, the pipe class is analyzed in the PCD as shown on S.50.06. If you have defined a pipe in the nominal size range from 15 to 100 in your pipe class without having selected the filter, the PCD would show the nominal size range from 15 to 100.

But if you select the Filter check box, the nominal sizes are broken down to all available sizes as can be seen on S.50.06. Our example would look as follows:

DN from

DN to

15

15

20

20

25

25

32

32

40

40

50

50

65

65

80

80

100

100

The Filter check box must be selected if you want to work with the branch option. See Branch Opt.