On this screen, all attributes needed by the PDMS interface must be defined.
You must not enter the attributes TYPE and NAME, because these are always part of the header and also always come at the beginning. Here only those attributes are defined that you need in addition.
The following table explains where Smart Materials gets the information if the attribute in the PDMS header is referenced.
Attribute |
Source in Smart Materials |
---|---|
ANGLE |
default is return value of M_PCK_PDMS_CUSTOM.S2008 |
BLTREF |
'/' and bolt_commodity_id and '-' and the value of the geometry attribute for the related ident, which is mapped on A.50.I.02 for ‘PDMS’ interface with the translation ‘BDIA’ |
CATREF |
interface commodity code (S.30.I.01 Window 2) |
CMPPREF |
‘/’ and Ident |
DETAIL |
'/' and Ident |
PBOR0 |
Nominal Size |
PBOR1 |
Nominal Size |
PBOR2 |
Nominal Size |
PBOR3 |
Nominal Size |
PBOR4 |
Nominal Size |
RADIUS |
default is return value of M_PCK_PDMS_CUSTOM.S2008 |
STYP |
default is return value of M_PCK_PDMS_CUSTOM.S2008 |
SUFF |
If option code = 1 THEN will be SUFF = ‘PREF', Else SUFF will take the first three characters of the option code |
SHOP |
default is return value of M_PCK_PDMS_CUSTOM.S2008 |
BDIA |
input 1 |
BTYP |
default is return value of M_PCK_PDMS_CUSTOM.S2008 |
BAUL |
the value of the geometry attribute for the related ident, which is mapped on A.50.I.02 for ‘PDMS’ interface translated as ‘LGTO’ |
MATXT |
default is return value of M_PCK_PDMS_CUSTOM.S2008 |
TEMP_ FROM |
Output1 in the Geometric Table for Insulation |
TEMP_TO |
Output2 in the Geometric Table for Insulation |
DN_FROM |
Nominal Size 1 in the Geometric Table for Insulation |
DN_TO |
Nominal Size 2 in the Geometric Table for Insulation |
INS_THK |
Output3 in the Geometric Table for Insulation |