This project default controls the project session lock timeout value for the Open MTO Interface (OMI) job execution while running online.

  • Module(s) affected by this setting: BOM Import, BOM Import Job Details, BOM Import Protocol, Review Data, and Run Procedures.

  • Default value: ./.

  • List of Values: -1 and 10 - 1500 (increment 10).

    • If set to -1, the Import and Compare > BOM Import page does not wait at all. When it detects that an another import job for the same project is currently running, it will time out immediately.

    • If set to other values between 10 - 1500, the Import and Compare > BOM Import page will wait for the specified number of seconds. This mechanism is necessary to serialize the jobs that import BOM data into the same project.