This section displays the positions and properties associated with nodes.
-
On the Home page, click Bill of Materials> Maintain BOM
-
In the BOM Configuration section, select the BOM view in the View name box.
-
Select the Issue Status from the list. the following options are available:
-
All Descending: When you select this, all Issue Statuses in order of latest first is used.
-
All Ascending: When you select this, all Issue Statuses in order of latest last is used.
-
Highest: This is the default value. When you select this, only highest available Issue Status on this BOM are used.
-
Lowest: When you select this, only lowest available Issue Status on this BOM are used.
-
Best Quantity: When you select this, only the Issue Status with the best quantity is used.
-
Selected: On selection of this option, only selected Issue Status on this BOM are used.
-
-
Enter a a valid issue status in the Select Issue Status box or select from the list.
If the issue status is Selected, the Selected Issue Status box is enabled.
-
Select the Include Sub Tree Nodes to include all subnodes.
-
Select the Use Incomplete Specifications check box to allow incomplete specifications (specifications without specifications Items) also in creating BOM positions.
-
Select the TSQ Required check box to indicate if transfer site quantity processing is necessary for this node.
-
If the ZX_ALLSPEC project default is set to N or not set at all, the select list only displays issued specs. If the ZX_DP_SPEC project default is set to Y, only specs created in the same discipline as the login discipline are displayed in the select list.