  1. Open a drawing.

  2. Select View > Apply Display Set to display the Apply Display Set dialog.

  3. Under the My Display Sets folder or the plant folder or the Auto Display Sets folder, select the display set.

    If needed, change the color and width of the drawing item lines to be applied by the filters in the display set. To hide an item on the drawing sheet, select None for the color.

  4. Select OK.

  • Filtering behavior for label colors depends on the value of the Filter for property in the label filter and the Do not show labels for filtered items check box setting on the View Properties dialog Display tab (the Labels check box must always be selected to enable the Do not show labels for filtered items check box). The following table summarizes the behavior.

    'Filter for' value

    'Do not show labels...' setting

    Resultant Behavior when Applying Display Set

    Label: Model Item

    Selected

    Label colors are independent of model item colors; labels are hidden when model items are hidden.

    Label: Model Item

    Cleared

    Label colors are independent of model item colors; labels display when model items are hidden.

    Label: Catalog Item (optional)

    Selected or cleared

    Label colors are the same as the model item colors; labels are hidden when model items are hidden.

  • When specifying line widths for display sets, you can set label graphics and leader lines to appear in the default width of the labels regardless of the line width value specified for model items. This option is specified by using a key 'IgnoreDisplaySetWidthOnLabels' under the 'Options' section of the Smart P&ID.ini file (located in the users\<username> folder) as shown:

    [options]

    WaterMarkWhileWorking=True

    WaterMarkWhilePrinting=True

    undosteps=0

    autogapping=False

    ConsistencyChecks=True

    .

    .

    .

    IgnoreDisplaySetWidthOnLabels=1

    The following table shows how the values assigned in the SmartPlantPID.ini file affect the output.

    Key Value

    Resultant Behavior when Applying Display Set

    IgnoreDisplaySetWidthOnLabels=1

    Label line widths are independent of model item line widths; label line widths are set to default value for labels.

    Label line widths are independent of model item line widths; line widths of label graphics and leader lines are set to the default value for labels.

    IgnoreDisplaySetWidthOnLabels=0

    Label line widths, including graphics and leader lines, are the same as the model item line widths.

    No key

    Label line widths, including graphics and leader lines, are the same as the model item line widths.

  • For a display set that contains one or more asking filters, on selecting Apply, the Asking Filters dialog opens with the default values for each asking filter, allowing you to change the operators and values of each asking filter's attributes, if desired. The attribute values you selected are used when saving or printing the drawing and those values are retained until the display set is cleared for that drawing. This applies on a per drawing basis; therefore if the same display set is applied to more than one drawing, you can enter different attribute values for each asking filter and those values are retained independently for each drawing.