This procedure explains how to enable the ISO 15926 (*.xml) option on the list of formats when using the Save As command in Drawing Manager.
-
You must have a valid license ID to perform this procedure successfully. To obtain a license and receive the license ID for the Smart P&ID ISO 15926 Export Utility, contact your local Intergraph Sales Representative.
-
The file PlantConfig.xml must be located in the Smart P&ID Reference Data folder. This file contains the mapping of the symbology and Heat Trace media line types between Smart P&ID and ISO 15926. If a line style is undefined in the mapping, Smart P&ID lines appear by default in the ISO output as 'solid'. To change the mapping default for an undefined line style, edit the following line in the file:
<action Style="Undefined" LineType="Solid"/>
-
At the command prompt, type the full path of the Drawing Manager executable file, for example:
c:\Program Files (x86)\SmartPlant\P&ID Workstation\bin\DrawingManagerEXE.exe. -
Add a space after the path and copy the license ID provided to you after the space.
-
Run the command to open Drawing Manager. The 'Save as' formats will include the ISO 15926 (*.xml) option as enabled.
To enable this option whenever Drawing Manager is opened, create a shortcut that includes the full path to the executable file and the license ID, and use this shortcut to start Drawing Manager.