If you chose the full installation of Smart P&ID, then you can test the connection with a plant structure that is already configured.

  1. Go to Start > Programs > Intergraph Smart P&ID > Drawing Manager.

  2. Go to File > Open Database.

  3. Select Site Servers and browse to a SmartPlantV4.ini file.

  4. Select the file and select OK.

  5. Select the plant structure in the Open Plant Structure dialog.

  6. Select Open, and the selected plant with its drawings appears in the Drawing Manager view.

If you experience problems connecting to the Smart P&ID site or getting into the plant structure, verify that the site server is running and ask the Smart P&ID administrator to set the PDS 3D users as Smart P&ID administrators during this configuration. You need administrator privileges until you start doing restrictions per plant structure. Smart P&ID permissions are handled in Smart Engineering Manager.