Limitations - Intergraph Smart P&ID - 11 - Help

Intergraph Smart P&ID Support Utilities

Language
English
Product
Intergraph Smart P&ID
Search by Category
Help
Smart P&ID Version
11
  1. When an actuator is replaced via the modification of the instrument valve’s Actuator Type property, the symbol will be replaced (if the appropriate symbol exists). However, there may be items that require clean up:

    1. Any instrument signal lines connected to the original actuator will require manual re-attachment.

    2. Any labels associated with the actuator will be deleted and require manual replacement.

    3. Rotation of the actuator on placement of the instrument valve is governed by the placement method used when placing the individual instrument valve (that is, cursor above line will place the actuator on top of the valve).

  2. If an instrument valve and its associated actuator are deleted from the model and processed in the same select set, the user will receive the following warning:

    Click OK, save the drawing and continue.