Enter Required ProgIDs - Intergraph Smart P&ID - 10 - Help - Hexagon

Intergraph Smart P&ID Utilities Help

Language
English
Product
Intergraph Smart P&ID
Subproduct
Utilities
Search by Category
Help
Smart P&ID Version
10
Smart Engineering Manager Version
11
  1. Select Start > SPEM > Data Dictionary Manager.

  2. Select Database Tables.

  3. Select each database table listed in the following table.

    Database Table

    Property

    Calculation ID

    Validation ID

    Case
    Process

    Pressure

    PipeSpec.Commodity
    CodeValidator

    Case
    Process

    Temperature

    PipeSpec.Commodity
    CodeValidator

    Inline Component

    NominalDiameter

    ValidateNomDiam.
    ForeignCalc

    Inline Component

    CommodityCode

    PipeSpec.Commodity
    CodeValidator

    Pipe Run

    PipingMaterialsClass

    PipeSpec.PMCFinder

    PipeSpec.Commodity
    CodeValidator

    *Pipe Run

    NominalDiameter

    PipeSpec.NPDFinder

    ValidateNomDiam.
    ForeignCalc

    *Pipe Run

    SP_PipeSpecRevision

    PipeSpec.Commodity
    CodeValidator

    *Piping Component

    OptionCode

    PipeSpec.OptionCode
    Finder

    PipeSpec.Commodity
    CodeValidator

The Calculation IDs for Nominal Diameter and SP_PipeSpecRevision in the Pipe Run table and Option Code in the Piping Component table (items marked with an (*) asterisk) are available only when the pipe specification source is Smart 3D or Smart Reference Data. These validations are not available when the piping specification source is PDS 3D.

  1. Double-click each property to display the Modify Property dialog. An example of the dialog is shown below.

    PPM All Outputs Graphic

  2. Type the information in the given fields as shown in the example above.

  3. Select OK to save your changes and close the dialog.

  4. Repeat steps 3 through 5 to update each database table.