The CSE displays all allowed component groups for all main/branch combinations as shown in the picture below.
Here is a sample file name for the specification branch file:
CDWRX_EJ_0000018630_SpecBranch.lst
with CDWRX indicating the product (CADWorx) and EJ_nnnnnnnnnn indicating the SRD export job number.
The branch file has the following format:
SPEC_NAME|MAIN_SIZE|BRANCH_SIZE|CMPNT_TYPE
150|.125|.125|9
The list is ordered by column 1, 2, 3. If there is more than one component type for the header/branch-combination, they will be listed in separate rows. The preferred option is always the first for equal combinations.
The branch table file can be filled from the branch table assigned in the specification header geometrics. After mapping commodity parts to component type sheets, the appropriate component types are filled in.
The standard attribute configuration coming with the installation scripts is listed below.
Attribute |
Default Value |
Dependencies |
Retrieval Method |
Source |
---|---|---|---|---|
SPEC_NAME |
BASE_COLUMN |
sh.spec_code |
||
NOM |
BASE_COLUMN |
gbd.dn_header |
||
SCH |
BASE_COLUMN |
gbd.dn_branch |
||
CMPNT_TYPE |
BASE_COLUMN |
m_pck_cdwrx_custom.get_component_type(m_pck_sp3d.g_im_id, gbd.group_id,gbd.part_id, NULL, NULL) |