You can manage general configuration item values.
-
Click Integration > PDMS > PDMS Transfer Jobs.
-
Click the General Configurations tab.
-
Double-click a general configuration in the tree view.
-
In the PDMS General Configuration Item Values grid, click Edit Grid .
-
Click Add Row , and select a general configuration item from the Selection list .
-
Type a description for the item in the Item Comment cell, and select a value from the Selection list in the Value cell.
-
Click Save Grid , and then click Read-Only Grid .
Set the AUTO_FILTER_VALVEOP_CLASS_SHTS_IN_SPEC configuration to Y to filter the valve operator part class data tables.
Following are the list of general configurations that you must select for the Ident or Specification transfer files:
File Name |
General Configuration |
Value |
---|---|---|
C.DAT |
|
Is picked from the Geometrics page |
F.DAT |
For all the Flange Components, you must define the Bolt Commodity Codes in the Spec Item grid page. |
|
BS.DAT |
|
|
M.DAT |
|
|
B.DAT |
No specific configurations |
|
G.DAT |
No specific configurations |