After creating the Report definition Unique ID, it must be specified on the module definition.
To specify the Report Definition Unique ID on the module Definition:
-
Navigate to the installation path ...\\SmartPlant\Smart WQMS\Models.
-
Open WQMS-Modules Excel file.
-
Navigate to ModuleSpecificProperties sheet > UpdateInstrutions section and edit the following property:
This sheet contains the list of all views except the NOI/ROI views of Smart Weld Quality Management System.
-
WQMSCustomReportDef - Specify the Report UID in this property.
For example:
-
If you want to place an icon in the Welder Qualification Test section in Welder module, enter "WelderQualificationTest:Report_Definition_Unique_ID" against the Update_WQMSAdminModule_ReferenceData_Welders field.
-
If you want to place the icon in Passed tab of the Welder Qualification List, enter "WelderQualificationList_PassedWQs:Report_Definition_Unique_ID" against the Update_WQMSAdminModule_ReferenceData_Welders field.
-
If you want to place icon in multiple sections, like Welder Log, Welder Qualification Test, and Welder Qualification List, enter "Welder:Report_Definition_Unique_ID|WelderQualificationTest:Report_Definition_Unique_ID|WelderQualificationList_PassedWQs:Report_Definition_Unique_ID" against the Update_WQMSAdminModule_ReferenceData_Welders.
If there are more than one Report Unique IDs then you can separate the Unique IDs with a comma ",".
-
-
To generate custom reports from the NOI or ROI module:
-
Navigate to the installation path ...\\SmartPlant\Smart WQMS\Models.
-
Open WQMS-Modules Excel file.
-
Navigate to InspectionDef sheet > WQMSInspectionDef section and edit the following properties:
-
WQMSInspDefNOICustomRptDef - Specify the Report Unique ID to generate the report from the NOI.
-
WQMSInspDefROICustomRptDef - Specify the Report Unique ID to generate the report from the ROI.
-