In Lead module, you can edit any data on a welds, except on rejected welds. Data cannot be edited in other modules as they might be disabled. The changes made in this module will reflect in all the modules.
-
Click Lead module.
-
In the search bar, enter *, select any filter criteria, and click Refresh .
The software displays all the ISO/Drawing Numbers that satisfy the filter criteria.
If you want particular drawing numbers to be displayed in the ISO/Drawing No list:
-
Copy the ISO/Drawing numbers from the Excel sheet and paste them in the Search bar. After you paste the drawing numbers in the Search bar, they are separated with the | symbol.
For example, If you copy two drawing numbers from the Excel sheet and paste them in the Search bar, the drawing numbers appear as as HXN81X-S91011-IS030015|HXN81X-S91011-IS030016 separated with the | symbol.
-
In the Search bar, type the ISO/Drawing number in the format below:
*last two digits of the drawing number* or *Drawing number pattern*
For example, if the drawing number is HXN81X-S91011-IS030015, in the Search bar, type *15* or type *S91011*. Then only the drawing numbers related to the pattern will be displayed in the ISO/Drawing No list.
This is applicable to all the modules of Weld Quality Management System where ever there is a filter criteria for ISO/Drawing numbers.
-
-
Select an ISO from the list, and all the welds on that ISO are displayed in the table.
-
Select a weld. The following properties on the weld must be read only:
-
CWP No.
-
ISO No.
-
Revision
-
Thickness1
-
Thickness2
-
SPEC
-
Inch Dia
-
-
Click the weld and edit the data.
-
Select a weld and click Assign Welders . The assigned welders for the weld are displayed in ASSIGN MULTIPLE WELDERS box.
-
Select the welder from the Selected Welders list and click left arrow to un-assign the existing welder.
-
Select the welder from Available Welders list and click right arrow to assign a new welder to the weld.
-
Click Generate Weld Cardto generate a report for the weld data.