Alternative Text - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Where applicable, each AText description includes its respective default value. If a default value is not specified, the AText is normally left blank.

For each AText, three options are available:

  • <Default> uses the default AText value.

  • <Suppress> suppresses the AText value.

  • <Edit value> modifies the AText value with the user-specified entry.

Field Fit Weld Callout

Plats a distinguishing message that points to a field fit weld. The default value is FFW.

AText ID:

-221

? Value:

None

$ Supported:

No

Seal Weld Label

Indicates the weld type for seal welds on the isometric drawing. The default value is SEAL WELD.

AText ID:

-425

? Value:

None

$ Supported:

No

Mitre Weld Label

Identifies mitre welds. The software edits the mitre angle into the text string at the ? position, which can be positioned anywhere in the string. The default value is MITRE ?.

AText ID:

-457

? Value:

Mitre Angle

$ Supported:

Yes

Site Weld Label

Points to a site weld. The value must be defined.

AText ID:

-498

? Value:

None

$ Supported:

No

Shop Text Weld Label

Point to a site weld or a field fit weld that requires a shop test weld be performed at the same location. Applies to welds with the symbol key WSST or WFST. The default value is SHOP TEST WELD.

AText ID:

-499

? Value:

None

$ Supported:

No

Offshore Weld Label

Points to an offshore weld if user-specified.

AText ID:

-501

? Value:

None

$ Supported:

No