Reorder Bypass
Controls by-pass component re-ordering. Select the checkbox to re-order components at by-pass closure points.
Defines:
Option Switch - 109, Pos 6
I-Configure - Supplementary.RepeatFile.ByPass
Component Information
Controls if and how component information is written to the repeatability return file.
-
Off suppresses writing component information to the repeatability return file.
-
With Numeric writes numeric component information to the file
-
With Alphabetic writes full alphanumeric component information to the file (4 character maximum).
Defines:
Option Switch - 109, Pos 5
I-Configure - Supplementary.RepeatFile.ComponentInfo
Content
Controls the type of repeatability return file output.
-
Standard outputs only of only successfully processed pipelines. This is the default setting for a standard repeatability return file type (FOR052).
-
Original outputs the original repeat information.
-
Revised outputs the original repeat information and new records for spool information.
-
Original ASCII outputs an ASCII version of the original repeat information.
-
Revised ASCII outputs an ASCII version of the original repeat information.
Defines:
Option Switch - 109, Pos 1
I-Configure - Supplementary.RepeatFile.Content
Part Numbers
Controls whether material list part number information is written to the repeatability return file. Select the checkbox to write material list part number information to the repeatability return file.
Defines:
Option Switch - 109, Pos 8
I-Configure - Supplementary.RepeatFile.MatList
Split Points
Controls whether split points are written to the repeatability return file. Select the checkbox to write split point information.
Defines:
Option Switch - 109, Pos 3
I-Configure - Supplementary.RepeatFile.SplitPoints
Spool Identifier
Controls whether spool identifier information is written to the repeatability return file.
-
Off suppresses writing any spool identifier information to the file.
-
Numeric writes spool identifier to the file.
-
Alphabetic writes full alphanumeric spool identifier information to the file (4 character maximum).
Defines:
Option Switch - 109, Pos 4
I-Configure - Supplementarty.RepeatFile.SpoolID
Start Point
Controls whether the start point for data extraction is written to the repeatability return file. Select the checkbox to write the data extraction start point.
Defines:
Option Switch - 109, Pos 2
I-Configure - Supplementary.RepeatFile.StartPoint
Weld Numbers
Controls whether weld number information is written to the repeatability return file. Select the checkbox to write the information to the file.
Defines:
Option Switch - 109, Pos 7
I-Configure - Supplementary.RepeatFile.WeldNos