Instrument Size - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Specifies the size of the enclosure for instrument text.

You can select 1 through 4 characters on each of the two available lines within an instrument balloon, or you can specify no balloon.

Click Show Collapse ICP to display a gallery of shapes, and then select the appropriate setting.

  • No Balloon suppresses plotting of a balloon around the instrument name.

  • 1 Character plots a balloon size at least 1 character on each line.

  • 2 Character plots a balloon size at least 2 character on each line.

  • 3 Character plots a balloon size at least 3 character on each line.

  • 4 Character plots a balloon size at least 4 character on each line.

  • 5 Character plots a balloon size at least 5 character on each line.

Defines:

Option Switch - 123, Pos 1
I-Configure - Drawing.Format.InstIDEnclosureSize

This property is not applicable for Smart 3D cabletray isometric drawings.