Controls the output of dimension text and messages.
Select the check box to place dimension text and messages along a section of pipe in isometric projection (oblique angle\slanted text). Text oblique angle is adjusted to be parallel to the dimension standout direction. Isogen attempts to set a vertical dimension standout for horizontal sections of pipeline wherever practical.
Defines:
Option Switch - 8, Pos 3
I-Configure - Drawing.Dimensions.IsometricText
This feature is available only for .dxf format output styles generated using the piping object data (POD) file interface.